    PE "METIZY-94" officially recognized as an exemplary taxpayerPE "METIZY-94" is included in the official list of taxpayers with a high level of voluntary compliance with the law. Order of the State Tax Service No. 1142 dated 11/28/2025 confirmed the company's status as a transparent and reliable market participant, which gives the right to simplified administration and personal compliance management.
  • 30.09.2025
    "Metizy-94" reduces prices on wire!The price of wire has dropped — low-carbon galvanized heat-treated and non-heat-treated, barbed galvanized single-core and double-core.
  • 08.09.2025
    ChP "Metizy-94" is again recognized as a reliable taxpayerChP "Metizy-94" once again confirms its status as a reliable taxpayer. This is evidence of the financial discipline and transparency of the company, which makes cooperation with it safe and profitable for partners and clients.

Why do you need a masonry grid? Answers to SNiP II-22-81

masonry mesh Why do you need a masonry grid?

The answer to this question is in SNiP II-22-81 " Stone and reinforced masonry structures "
Paragraph 6.75 says that horizontal reinforcement of brickwork joints is necessary only in cases where an increase in the grade of brick, stone and mortar does not provide the necessary strength of the masonry and the cross-sectional area of \u200b\u200bthe masonry cannot be increased. The amount of masonry meshshould be at least 0.1% of the masonry volume (see clause 4.30 of this SNiPa).

After how many rows should the masonry mesh be laid?

Paragraph 6.76 says that the masonry mesh must be laid at least after five rows of brickwork from ordinary bricks, after four rows of masonry if thickened bricks are used, after three rows of masonry if the masonry is made of ceramic stones.

There are a large number of cheap masonry mesh on the market made of wire 2.7-2.9, but what does SNiP allow?

Item 6.77. prohibits the use of wire mesh smaller than 3 mm.

What is the maximum wire diameter for masonry mesh?

The maximum diameter of the wire from which the grid for laying bricks is made, according to building codes and regulations, cannot exceed 6 mm, but if, instead of the grid, reinforcement laid with a "snake" is used, then, in this case, the diameter of the reinforcement should not exceed 8 mm.

What cell should this grid have?

SNiP II-22-81 regulates the distance between the wires from 30 to 120 mm.

What is the thickness of the seam should be when using construction mesh?

SNiP II-22-81 indicates that the thickness of the seam, in this case, should be 4 mm greater than the sum of the diameters of the crossing wires. This means that the solution layer should cover the wire by approximately 2 mm on each side.

A masonry mesh TM Kazachka from perforated metal appeared on the market. Does it comply with SNiP II-22-81?

This SNiP regulates the use of masonry mesh only if the brick does not provide sufficient masonry strength. In other cases, the building mesh is used for additional insurance, to prevent the appearance of cracks in the walls, so the builder or the customer himself determines the need to use one or another mesh.